* ath79: convert devices to interrupt-driven gpio-keysAdrian Schmutzler2019-09-221-2/+2
| | | | | | | | | | | | | This converts all remaining devices to use interrupt-driven gpio-keys compatible instead of gpio-keys-polled. The poll-interval is removed. Only ar7240_netgear_wnr612-v2 is kept at gpio-keys-polled, as this one is using ath9k keys. Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de> Tested-by: Karl Palsson <karlp@etactica.com> Tested-by: Dmitry Tunin <hanipouspilot@gmail.com>
* ath79: provide label MAC addressAdrian Schmutzler2019-09-191-0/+1
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | This patch adds the label MAC address for several devices in ath79. Some devices require setting the MAC address in 02_network: For the following devices, the netif device can be linked in device tree, but the MAC address cannot be read: - alfa-network,ap121f - avm,fritz300e - ubnt-xm devices For the following devices, label MAC address is tied to lan or wan, so no node to link to exists in device tree: - adtran,bsap1800-v2 - adtran,bsap1840 - dlink,dir-842-c1/-c2/-c3 - engenius,ecb1750 - iodata,etg3-r - iodata,wn-ac1167dgr - iodata,wn-ac1600dgr - iodata,wn-ac1600dgr2 - iodata,wn-ag300dgr - nec,wg800hp - nec,wg1200cr - trendnet,tew-823dru Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
* ath79: Add missing read-only propertiesAdrian Schmutzler2019-05-111-0/+1
| | | | | | | | | Add some read-only properties to protect partitions from accidental changes. Also fixed two whitespaces error on the way. Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
* ath79: Add GL.iNet AR-300M-LiteJeff Kletsky2019-03-131-8/+49
| | | | | | | | | | | | | | | | | | | | | AR300M-Lite is single-Ethernet variant of the AR300M series Its eth0 would otherwise be assigned to the WAN interface making it unreachable firstboot or failsafe. Installation instructions from OEM (OpenWrt variant): * Install sysupgrade.bin using OEM's "Advanced" GUI (LuCI), * Do not preserve settings * Access rebooted device via Ethernet at OpenWrt default address Add previously missing LED defaults for all three variants; -nand, -nor, -lite to the definitions in 01_leds Non-lite variants thanks to Andreas Ziegler https://patchwork.ozlabs.org/patch/1049396/ Runtime-tested: GL.iNet AR300M-Lite Signed-off-by: Jeff Kletsky <git-commits@allycomm.com>
* ath79: Modify glinet x750 and AR300m MAC address offsetsLuo chongjun2019-02-281-1/+2
| | | | | | | | In the production of glinet, the MAC address of ethernet port is only written at the position where the ART area offset address is 0, and the MAC address of eth1 is added 1 on the basis of eth0. Signed-off-by: Luo chongjun <luochongjun@gl-inet.com>
* ath79: fix GL.iNet AR300M family GPIOs/LEDsJeff Kletsky2019-01-261-14/+2
| | | | | | | | | | | | | | | | | Change the "status" LED to proper GPIO 12 and "red" naming. Remove GPIO 2 from definition as a USB LED. GPIO 2 is used to control power to the USB socket, not an LED. As such, PWM on the line or typical LED triggers are inappropriate. Users who wish to control the USB power for custom applications can manipulate the GPIO through code, or for example, export it through /sys/class/gpio/export. Runtime-tested:  GL.iNet AR300M-Lite Signed-off-by: Jeff Kletsky <git-commits@allycomm.com>
* ath79: add status LED on GL.iNet AR300MPaul Wassi2018-12-311-1/+8
| | | | | | This adds the triggers for the status LED of this device. Signed-off-by: Paul Wassi <p.wassi@gmx.at>
* ath79: fix boardname of GL.iNet GL-AR300MPaul Wassi2018-12-311-0/+99
This device is called GL-AR300M, therefore rename the board(s) to 'gl-ar300m-nor' and 'gl-ar300m-nand' Signed-off-by: Paul Wassi <p.wassi@gmx.at> [change boardname in uboot envtools as well, don't use wildcards for boardname] Signed-off-by: Mathias Kresin <dev@kresin.me>