aboutsummaryrefslogtreecommitdiffstats
path: root/target/linux/realtek/files-5.10
Commit message (Collapse)AuthorAgeFilesLines
* realtek: use correct CAUSEF_DC macro in prom.cSander Vanheule2022-10-011-1/+1
| | | | | | | | The workaround for an already-enabled R4K timer used a non-existent macro CAUSE_DC. Fix compiling by using the actual macro CAUSEF_DC. Fixes: b7aab1958591 ("realtek: SMP handling of R4K timer interrupts") Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: SMP handling of R4K timer interruptsMarkus Stockhausen2022-10-011-3/+9
| | | | | | | | | | | | | | | | | | | Until now there has been no good explanation why we mess with the R4K timer on SMP. After extensive testing and looking at the SDK code it becomes clear what it is all about. When we disable the CEVT_R4K module (we will do with the new timer driver) the R4K timer hardware still fires interrupts on the secondary CPU. To get around this we have two options: - Disable IRQ 7 - Stop the counter completely This patch selects option two because this is the root of evil.. To be on the safe side we will do it only in case the CEVT_R4K module is disabled. Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: fix SMP startupMarkus Stockhausen2022-10-011-2/+1
| | | | | | | | The scope of the SMP startup structure is wrong. It is created on the stack and not as a global variable. This can lead to startup failures. Fixes: 3f41360eb70c ("realtek: use upstream recommendation for CPU start") Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de
* realtek: fix RTL839x egress tag for ports >= 32Jan Hoffmann2022-09-251-1/+1
| | | | | | | Don't overwrite AS_DPM and L2LEARNING flags when dest_port is >= 32. Fixes: 1773264a0c6d ("realtek: correct egress frame port verification") Signed-off-by: Jan Hoffmann <jan@3e8.eu>
* realtek: use upstream recommendation for secondary CPU startMarkus Stockhausen2022-09-181-5/+31
| | | | | | | | | | | Currently we fix interrupts/timers for the secondary CPU by patching vsmp_init_secondary(). Get a little bit more generic and use the upstream recommended way instead. Additionally avoid a check around register_cps_smp_ops() because it does that itself. See https://lkml.org/lkml/2022/9/12/522 Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: rtl838x: Fix ethernet polling timeout on probeOlliver Schinagl2022-09-141-1/+2
| | | | | | | | | | Due to an oversight we accidentally inverted the timeout check. This patch corrects this. Fixes: 9cec4a0ea45b ("realtek: Use built-in functionality for timeout loop") Signed-off-by: Olliver Schinagl <oliver@schinagl.nl> [ wrap poll_timeout line to 80 char ] Signed-off-by: Christian Marangi <ansuelsmth@gmail.com>
* realtek: Use built-in functionality for timeout loopOlliver Schinagl2022-09-141-12/+7
| | | | | | | | | | In commit 81e3017609be ("realtek: clean up rtl838x MDIO busy wait loop") a hand-crafted loop was created, that nearly exactly replicate the iopoll's `read_poll_timeout` functionality. Use that instead. Signed-off-by: Olliver Schinagl <oliver@schinagl.nl>
* realtek: fix RTL839x receive tag decodingBjørn Mork2022-09-091-2/+2
| | | | | | | | | | The previous fixup was incomplete, and the offsets for the queue and crc_error cpu_tag bitfields were still wrong on RTL839x. Fixes: 545c6113c93b ("realtek: fix RTL838x receive tag decoding") Suggested-by: Jan Hoffmann <jan@3e8.eu> Signed-off-by: Bjørn Mork <bjorn@mork.no>
* realtek: fix RTL838x receive tag decodingBjørn Mork2022-09-081-3/+6
| | | | | | | | | | | | | | | | | | | Commit dc9cc0d3e2a1 ("realtek: add QoS and rate control") replaced a 16 bit reserved field in the RTL83xx packet header with the initial cpu_tag word, shifting the real cpu_tag fields by one. Adjusting for this new shift was partially forgotten in the new RX tag decoders. This caused the switch to block IGMP, effectively blocking IPv4 multicast. The bug was partially fixed by commit 9d847244d9fd ("realtek: fix RTL839X receive tag decoding") Fix on RTL838x too, including correct NIC_RX_REASON_SPECIAL_TRAP value. Suggested-by: Jan Hoffmann <jan@3e8.eu> Fixes: dc9cc0d3e2a1 ("realtek: add QoS and rate control") Signed-off-by: Bjørn Mork <bjorn@mork.no>
* realtek: fix PLL register inconsistenciesMarkus Stockhausen2022-08-311-0/+3
| | | | | | | Some devices have wrong/empty values in the PLL registers. Work around that by reporting the default values. Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: ignore disabled switch portsSander Vanheule2022-08-291-0/+3
| | | | | | | | | | | | | | | | | | | | | | | | | | | When marking a switch port as disabled in the device tree, by using 'status = "disabled";', the switch driver fails on boot, causing a restart: CPU 0 Unable to handle kernel paging request at virtual address 00000000, epc == 802c3064, ra == 8022b4b4 [ ... ] Call Trace: [<802c3064>] strlen+0x0/0x2c [<8022b4b4>] start_creating.part.0+0x78/0x194 [<8022bd3c>] debugfs_create_dir+0x44/0x1c0 [<80396dfc>] rtl838x_dbgfs_port_init+0x54/0x258 [<80397508>] rtl838x_dbgfs_init+0xe0/0x56c This is caused by the DSA subsystem (mostly) ignoring the port, while rtl83xx_mdio_probe() still extracts some details on this disabled port from the device tree, resulting in the usage of a NULL pointer where a port name is expected. By not probing ignoring disabled ports, no attempt is made to create a debugfs directory later. The device then boots as expected without the disabled port. Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: add RTL83XX clock driverMarkus Stockhausen2022-08-286-0/+1151
| | | | | | | | | | | | | | | | | | | Add a new self-contained combined clock & platform driver that allows to access the PLL hardware clocks of RTL83XX devices. Currently it provides info about CPU, MEM and LXB clocks on RTL838X and RTL839X devices and additionally allows to change the CPU clocks. Changing the clocks multiple times on a DGS-1210-20 and a DGS-1210-52 already works well and is multithreading safe on the RTL839X. Even a cpufreq initiated change of the CPU clock works fine. Loading the driver will add some meaningful logging. [0.000000] rtl83xx-clk: initialized, CPU 500 MHz, MEM 300 MHz (8 Bit DDR3), LXB 200 MHz [0.279456] rtl83xx-clk soc:clock-controller: rate setting enabled, CPU 325-600 MHz, MEM 300-300 MHz, LXB 200-200 MHz, OVERCLOCK AT OWN RISK Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de> [remove trailing whitespaces, C-style SPDX comments for ASM and headers] Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: add PLL DT binding includesMarkus Stockhausen2022-08-281-0/+15
| | | | | | Add some constants for sharing between DT and drivers. Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: more generic platform initializationMarkus Stockhausen2022-08-201-5/+34
| | | | | | | | | Platform startup still "guesses" the CPU clock speed by DT fixed values. If possible take clock rates from a to be developed driver and align to MIPS generic platfom initialization code. Pack old behaviour into a fallback function. We might get rid of that some day. Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: clean up rtl838x MDIO busy wait loopJan Hoffmann2022-07-281-15/+22
| | | | | | | | | | | | | Don't use udelay to allow other kernel tasks to execute if the kernel has been built without preemption. Also determine the timeout based on jiffies instead of loop iterations. This is especially important on devices containing a watchdog with a short timeout. Without this change, the watchdog is not serviced during PHY patching which can take multiple seconds. Tested-by: Birger Koblitz <mail@birger-koblitz.de> Signed-off-by: Jan Hoffmann <jan@3e8.eu>
* realtek: add SFP support for RTL8214FC PHYJan Hoffmann2022-07-281-1/+25
| | | | | | | | | | Probe the SFP module during PHY initialization and implement insertion/removal handlers to automatically configure the media type of the respective port. Suggested-by: Birger Koblitz <git@birger-koblitz.de> Tested-by: Birger Koblitz <mail@birger-koblitz.de> Signed-off-by: Jan Hoffmann <jan@3e8.eu>
* realtek: rtl83xx-phy: decouple RTL8214FC media change and power configJan Hoffmann2022-07-281-52/+70
| | | | | | | | | | | | | Move RTL8214FC power configuration to newly created suspend and resume methods. A media change now only results in power configuration if the PHY is not suspended, to avoid powering up a port when the interface is currently not up. While at it, remove the rtl8380 prefix from function names, as this is actually not SoC-specific. Tested-by: Birger Koblitz <mail@birger-koblitz.de> Signed-off-by: Jan Hoffmann <jan@3e8.eu>
* realtek: rtl83xx-phy: fix RTL8214FC media changeJan Hoffmann2022-07-281-16/+16
| | | | | | | | Toggle power on the individual PHY instead of the package. Otherwise a media change always toggles power on the first port, and not the one that is being configured. Signed-off-by: Jan Hoffmann <jan@3e8.eu>
* realtek: correct egress frame port verificationSander Vanheule2022-07-172-39/+36
| | | | | | | | | | | | | | | | | | | | Destination switch ports for outgoing frame can range from 0 to CPU_PORT-1. Refactor the code to only generate egress frame CPU headers when a valid destination port number is available, and make the code a bit more consistent between different switch generations. Change the dest_port argument's type to 'unsigned int', since only positive values are valid. This fixes the issue where egress frames on switch port 0 did not receive a VLAN tag, because they are sent out without a CPU header. Also fixes a potential issue with invalid (negative) egress port numbers on RTL93xx switches. Reported-by: Arınç ÜNAL <arinc.unal@xeront.com> Suggested-by: Birger Koblitz <mail@birger-koblitz.de> Tested-by: Luiz Angelo Daros de Luca <luizluca@gmail.com> Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: correct egress frame priority assignmentSander Vanheule2022-07-171-12/+14
| | | | | | | | | | | | | | | | | | | | | | | | Priority values passed to the egress (TX) frame header initialiser are invalid when smaller than 0, and should not be assigned to the frame. Queue assignment is then left to the switch core logic. Current code for RTL83xx forces the passed priority value to be positive, by always masking it to the lower bits, resulting in the priority always being set and enabled. RTL93xx code doesn't even check the value and unconditionally assigns the (32 bit) value to the (5 bit) QID field without masking. Fix priority assignment by only setting the AS_QID/AS_PRI flag when a valid value is passed, and properly mask the value to not overflow the QID/PRI field. For RTL839x, also assign the priority to the right part of the frame header. Counting from the leftmost bit, AS_PRI and PRI are in bits 36 and 37-39. The means they should be assigned to the third 16 bit value, containing bits 32-47. Tested-by: Luiz Angelo Daros de Luca <luizluca@gmail.com> Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: fix egress L2 learning on rtl839xSander Vanheule2022-07-171-1/+1
| | | | | | | | | | | | The flag to enable L2 address learning on egress frames is in CPU header bit 40, with bit 0 being the leftmost bit of the header. This corresponds to BIT(7) in the third 16-bit value of the header. Correctly set L2LEARNING by fixing the off-by-one error. Fixes: 9eab76c84e31 ("realtek: Improve TX CPU-Tag usage") Tested-by: Luiz Angelo Daros de Luca <luizluca@gmail.com> Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: fix egress port mask on rtl839xSander Vanheule2022-07-171-1/+1
| | | | | | | | | | | | The flag to enable the outgoing port mask is in CPU header bit 43, with bit 0 being the leftmost bit of the header. This corresponds to BIT(4) in the third 16-bit value of the header. Correctly set AS_DPM by fixing the off-by-one error. Fixes: 9eab76c84e31 ("realtek: Improve TX CPU-Tag usage") Tested-by: Luiz Angelo Daros de Luca <luizluca@gmail.com> Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: remove hardcoded sys-led configurationsSander Vanheule2022-07-101-40/+0
| | | | | | | | | | | | setup.c unconditionally sets the sys-led mode (blinking rate) to a permanent high output. This may cause issues when a board expects this pin to toggle periodically, e.g. when hooked up to an external watchdog. If the sys-led peripheral is used to control an LED, the mux should be configured to use the pin as GPIO0, allowing for better control as a GPIO LED. Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: cleanup LAG loggingMarkus Stockhausen2022-06-261-12/+14
| | | | | | | | Setting up DSA bond silently fails if mode is not 802.3ad. Add log message to fix it. As we are already here harmonize all logging messages in the add/delete functions. Signed-off-by: Markus Stockhausen <markus.stockhausen@gmx.de>
* realtek: fix gcc-12 build with -Werror=array-compareBjørn Mork2022-06-221-1/+1
| | | | | | | | | Removing this gcc-12 error: arch/mips/rtl838x/setup.c:64:30: error: comparison between two arrays [-Werror=array-compare] 64 | else if (__dtb_start != __dtb_end) Signed-off-by: Bjørn Mork <bjorn@mork.no>
* realtek: do not reset SerDes on link changeBirger Koblitz2022-05-112-1/+3
| | | | | | | | | | | | | | | | | | | | | | | | | | | | Do not reset the RTL930x SerDes on link changes, instead set up the SDS with internal PHYs for the SFP+ ports only. This fixes the 8 1GBit ports on the Zyxel XGS1250 which do not work without this patch. A complete SerDes reset was performed on all SerDes links. For copper 1Gbit ports, this is commonly a single XGMII link to an RTL8218D. There is however no support for setting up the XGMII link on RTL9300/RTL9310, thereby wiping the (RX/TX) setup done by u-boot and breaking the 1GBit ports. No SerDes reset should be done for these links. The handling of SGMII/HiSGMII, 1000BX or 10GR links is actually entirely different. All these modes need to be suitably RX calibrated and the pre- main and post- amplifiers set up properly for TX. The 10GBit SFP+ fiber links are recalibrated instead of reset, which e.g. is necessary when someone pulls a module out and puts another in. This makes swapping out 10GBit fiber modules possible. 1GBit modules are not yet supported, nor any modules with an internal phy. Tested-by: Stijn Segers <foss@volatilesystems.org> Signed-off-by: Birger Koblitz <git@birger-koblitz.de> [rewrite commit message based on discussion] Link: http://lists.infradead.org/pipermail/openwrt-devel/2022-May/038623.html Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: Trap all frames with switch as destination to CPU-portBirger Koblitz2022-05-081-0/+9
| | | | | | | | | | | | This fixes a bug where frames sent to the switch itself were flooded to all ports unless the MAC address of the CPU-port was learned otherwise. Tested-by: Wenli Looi <wlooi@ucalgary.ca> Tested-by: Bjørn Mork <bjorn@mork.no> Signed-off-by: Birger Koblitz <git@birger-koblitz.de> [fix code formatting] Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: remove debugging code from timerSander Vanheule2022-02-201-15/+3
| | | | | | | Remove some (dead) debugging code from the Realtek timer to clean up the sources of this driver. Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: use DT provided address for timersSander Vanheule2022-02-201-23/+23
| | | | | | | | | | | | | | | The I/O base address for the timers was hardcoded into the driver, or derived from the HW IRQ number as an even more horrible hack. All supported SoC families have these timers, but with hardcoded addresses the code cannot be reused right now. Request the timer's base address from the DT specification, and store it in a private struct for future reference. Matching the second interrupt specifier, the address range for the second timer is added to the DT specification. Signed-off-by: Sander Vanheule <sander@svanheule.net>
* realtek: fix locking bug in rtl838x_hw_receive()Birger Koblitz2022-02-181-3/+4
| | | | | | | | | | | | | | A Locking bug in the packet receive path was introduced with PR #4973. The following patch prevents the driver from locking after a few minutes with an endless flow of [ 1434.185085] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000f8 [ 1434.208971] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc [ 1434.794800] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc [ 1435.049187] rtl838x-eth 1b00a300.ethernet eth0: Ring contention: r: 0, last a28000f4, cur a28000fc Signed-off-by: Bjørn Mork <bjorn@mork.no> Signed-off-by: Birger Koblitz <mail@birger-koblitz.de>
* realtek: add RTL8231 chip detectionSander Vanheule2022-02-171-1/+14
| | | | | | | | | | | | | | | | | | | | | | When initialising the driver, check if the RTL8231 chip is actually present at the specified address. If the READY_CODE value does not match the expected value, return -ENXIO to fail probing. This should help users to figure out which address an RTL8231 is configured to use, if measuring pull-up/-down resistors is not an option. On an unsuccesful probe, the driver will log: [ 0.795364] Probing RTL8231 GPIOs [ 0.798978] rtl8231_init called, MDIO bus ID: 30 [ 0.804194] rtl8231-gpio rtl8231-gpio: no device found at bus address 30 When a device is found, only the first two lines will be logged: [ 0.453698] Probing RTL8231 GPIOs [ 0.457312] rtl8231_init called, MDIO bus ID: 31 Signed-off-by: Sander Vanheule <sander@svanheule.net> Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
* realtek: always require SMI bus ID for RTL8231Sander Vanheule2022-02-171-17/+16
| | | | | | | | | | | | | | | The SMI bus ID for RTL8231 currently defaults to 0, and can be overridden from the devicetree. However, there is no value check on the DT-provided value, aside from masking which would only cause value wrap-around. Change the driver to always require the "indirect-access-bus-id" property, as there is no real reason to use 0 as default, and perform a sanity check on the value when probing. This allows the other parts of the driver to be simplified a bit. Signed-off-by: Sander Vanheule <sander@svanheule.net> Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
* realtek: use automatic GPIO numbering for RTL8231Sander Vanheule2022-02-171-1/+1
| | | | | | | | | Set the gpio_chip.base to -1 to use automatic GPIO line indexing. Setting base to 0 or a positive number is deprecated and should not be used. Signed-off-by: Sander Vanheule <sander@svanheule.net> Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
* realtek: fix RTL8231 gpio countSander Vanheule2022-02-171-1/+1
| | | | | | | | | | The RTL8231's gpio_chip.ngpio was set to 36, which is the largest valid GPIO index. Fix the allowed number of GPIOs by setting ngpio to 37, the actual line count. Reported-by: INAGAKI Hiroshi <musashino.open@gmail.com> Signed-off-by: Sander Vanheule <sander@svanheule.net> Tested-by: Stijn Tintel <stijn@linux-ipv6.be>
* realtek: rtl83xx-phy: abstract and document PHY featuresDaniel Golle2022-02-171-114/+135
| | | | | | | | | | | | | Replace magic values with more self-descriptive code now that I start to understand more about the design of the PHY (and MDIO controller). Remove one line before reading RTL8214FC internal PHY id which turned out to be a no-op and can hence safely be removed (confirmed by INAGAKI Hiroshi[1]) [1]: https://github.com/openwrt/openwrt/commit/df8e6be59a1fbce3f8c6878fe7440a129b1245d6#r66890713 Signed-off-by: Daniel Golle <daniel@makrotopia.org>
* realtek: fix locking issuesBirger Koblitz2022-02-172-26/+22
| | | | | | | Fixe a coupld of locking issues found by applying lock debugging to the code. Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: switch to use generic MDIO accessor functionsDaniel Golle2022-02-175-473/+398
| | | | | | | | Instead of directly calling SoC-specific functions in order to access (paged) MII registers or MMD registers, create infrastructure to allow using the generic phy_*, phy_*_paged and phy_*_mmd functions. Signed-off-by: Daniel Golle <daniel@makrotopia.org>
* realtek: implement Clause-45 MDIO write on rtl931xDaniel Golle2022-02-172-26/+65
| | | | | | | | | * Add missing Clause-45 write support for rtl931x * Switch to use helper functions in all Clause-45 access functions to make the code more readable. * More meaningful/unified debugging output (dynamic kprintf) Signed-off-by: Daniel Golle <daniel@makrotopia.org>
* realtek: add support for port led configuration on RTL93XXBirger Koblitz2022-02-176-8/+175
| | | | | | | | | Using the led-set attribute of a port in the dts we allow configuration of the port leds. Each led-set is being defined in the led-set configuration of the .dts, giving a specific configuration to steer the port LEDs via a serial connection. Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add support for the RTL8221B PHYBirger Koblitz2022-02-172-0/+18
| | | | | | | | | The RTL8221B PHY is a newer version of the RTL8226, also supporting 2.5GBit Ethernet. It is found with RTL931X devices such as the EdgeCore ECS4125-10P Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add specific PHY polling options to support the Zyxel XGS1250/XGS1210Birger Koblitz2022-02-172-14/+101
| | | | | | | | | | Both the Aquantia AQR113c and the RTL8226 PHYs in the Zyxel XGS1250 and the Zyxel XGS1210 require special polling configuration settings in the RTL930X_SMI_10GPHY_POLLING_REGxx_CFG configuration registers. Set them. Additionally, for RTL 1GBit phys set the RTL930X_SMI_PRVTE_POLLING_CTRL bits in the poll mask. Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Fix link status detection on RTL9302 for SFP modulesBirger Koblitz2022-02-172-3/+23
| | | | | | | For SFP slots on the RTL9302, the link status is not correctly detected. Use the link media status instead. Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add RTL931X sub-targetBirger Koblitz2022-02-171-0/+25
| | | | | | | | We add the RTL931X sub-target with kernel configuration for a dual core MIPS InterAptive CPU. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add HW support for RTL931X for PIE, L2 and STP agingBirger Koblitz2022-02-172-52/+1188
| | | | | | | | We add HW support routines for the RTL931X SoC family for handling the Packet Inspection Engine, L2 table handling and STP aging. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Store and Restore MC memberships for port enable/disableBirger Koblitz2022-02-172-55/+86
| | | | | | | | | We need to store and restore MC memberships in HW when a port joins or leaves a bridge as well as when it is enabled or disabled, as these properties should not change in these situations. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Copy all BPDUs to the kernelBirger Koblitz2022-02-174-8/+140
| | | | | | | | In order to receive STP information at the kernel level, we make sure that all Bridge Protocol Data Units are copied to the CPU-Port. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add L2 aging configuration functions for all SoC familiesBirger Koblitz2022-02-176-19/+58
| | | | | | | | Instead of a generic L2 aging configuration function with complex logic, we implement an individual function for all SoC types. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realted: Add DSA bridge offload configurationBirger Koblitz2022-02-174-1/+139
| | | | | | | | Add functionality to enable or disable L2 learning offload and port flooding for RTL83XX. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Add Link Aggregation (aka trunking) supportBirger Koblitz2022-02-178-15/+369
| | | | | | | | | This adds LAG support for all 4 SoC families, including support ofr the use of different distribution algorithm for the load- balancing between individual links. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>
* realtek: Cleanup setting inner/outer PVID and Ingress/Egres VLAN filteringBirger Koblitz2022-02-176-28/+189
| | | | | | | | Use setting functions instead of register numbers in order to clean up the code. Also use enums to define inner/outer VLAN types and the filter type. Signed-off-by: Sebastian Gottschall <s.gottschall@dd-wrt.com> Signed-off-by: Birger Koblitz <git@birger-koblitz.de>