1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
|
.. program:: ghdl
.. _USING:Invoking:
Invoking GHDL
#############
The form of the :program:`ghdl` command is ``ghdl command [options...]``.
There are multiple available commands, but these general rules apply:
* The first argument selects the command.
The options are used to slightly modify the action.
* No option is allowed before the command.
Except for the run command, no option is allowed after a filename or a unit name.
.. HINT::
If the number of options is large and the command line length is beyond the system limit, you can use a response file.
An argument that starts with a ``@`` is considered as a response file; it is replaced by arguments read from the file
(separated by blanks and end of line).
.. HINT::
Only the most common commands and options are shown here. For the most advanced and experimental features see section
:ref:`REF:Command`.
.. WARNING::
During analysis and elaboration GHDL may read the ``std`` and ``ieee`` files.
The location of these files is based on the prefix, which is (in order of priority):
* the :option:`--PREFIX` command line option
* the :envvar:`GHDL_PREFIX` environment variable
* a built-in default path. It is a hard-coded path on GNU/Linux, and it corresponds to the value of the
``HKLM\Software\Ghdl\Install_Dir`` registry entry on Windows.
You should use the :option:`--disp-config` command to display and debug installation problems.
Design building commands
========================
The most commonly used commands of GHDL are those to analyze and elaborate a design.
.. index:: cmd analysis
.. _Analysis:command:
Analysis [``-a``]
-----------------
.. option:: -a <[options...] file...>
Analyzes/compiles one or more files, and creates an object file for each source file.
Any argument starting with a dash is an option, the others are filenames.
No options are allowed after a filename argument.
GHDL analyzes each filename in the given order, and stops the analysis in case of error (remaining files are not
analyzed).
See :ref:`GHDL:options`, for details on the GHDL options.
For example, to produce debugging information such as line numbers, use: ``ghdl -a -g my_design.vhdl``.
.. index:: cmd elaboration
.. _Elaboration:command:
Elaboration [``-e``]
--------------------
.. option:: -e <[options...] [library.]top_unit [arch]>
Re-analyzes all the configurations, entities, architectures and package declarations, and creates the default
configurations and the default binding indications according to the LRM rules.
It also generates the list of object files required for the executable.
Then, it links all these files with the runtime library (GRT).
The elaboration command, :option:`-e`, must be followed by a ``top_unit`` name denoting either of:
* a configuration unit
* an entity unit
* an entity unit followed by a secondary unit (the name of an architecture unit)
* Name of the top units can be either a simple name (without dots), or the name of a logical library followed by a dot
and a simple name.
The latter is equivalent to using :option:`--work=NAME <--work>` described in :ref:`GHDL:options`:
``-e <[options...] --work=library top_unit [arch]>``.
It selects the name of the library to be used as ``WORK``.
See section :ref:`Top_entity`, for the restrictions on the root/top unit of a hierarchy.
* Name of the secondary units must be a simple name; they cannot contain any dot.
With regard to the artifacts:
* If the GCC/LLVM backend was enabled during the compilation of GHDL, the elaboration command creates an executable
containing the code of the VHDL sources, the elaboration code and simulation code for executing a design hierarchy.
The executable is created in the current directory and the the filename is the name of the primary unit, or for the
latter case, the concatenation of the name of the primary unit, a dash, and the name of the secondary unit.
Option ``-o`` followed by a filename can override the default executable filename.
* If mcode is used, this command elaborates the design but does not generate anything.
Since the run command also elaborates the design, this can be skipped.
.. WARNING::
This elaboration command is not a complete elaboration in terms of the VHDL standard.
The actual elaboration is performed at runtime.
Therefore, in order to get a complete VHDL elaboration without running the simulation, ``ghdl --elab-run --no-run``
is required.
See :option:`--no-run`.
.. index:: cmd run
.. _Run:command:
Run [``-r``]
------------
.. option:: -r <[options...] [library.]top_unit [arch] [simulation_options...]>
Runs/simulates a design.
Two sets of options are accepted, both of them being separated by ``[library.]top_unit [arch]``.
For the first set, ``options...``, arguments are the same as for the :ref:`elaboration command <Elaboration:command>`.
For the second set, ``simulation_options...``, arguments are defined in :ref:`USING:Simulation`.
* GGC/LLVM: the filename of the executable is determined and it is executed.
Elaboration options are ignored.
You may also directly execute the program.
The executable must be in the current directory.
* mcode: the design is elaborated and the simulation is launched.
As a consequence, you must use the same options used during analysis.
This command exists for three reasons:
* It works with mcode implementation, where the executable code is generated in memory.
* You are using GCC/LLVM, but you don't need to create the executable program name.
* It is coherent with the :option:`-a` and :option:`-e` commands.
.. index:: cmd elaborate and run
.. _elab_and_run:command:
Elaborate and run [``--elab-run``]
----------------------------------
.. option:: --elab-run <[options...] [library.]top_unit [arch] [simulation_options...]>
Acts like the elaboration command followed by the run command.
Note that this command accepts two sets of options.
See :option:`-e`, :option:`-r` and :ref:`USING:Simulation`.
.. index:: cmd checking syntax
Check syntax [``-s``]
---------------------
.. option:: -s <[options] files>
Analyze files but do not generate code.
This command may be used to check the syntax of files.
It does not update the library.
.. index:: cmd analyze and elaborate
Analyze and elaborate [``-c``]
------------------------------
.. option:: -c <[options] file... -<e|r> top_unit [arch]>
.. HINT::
With GCC/LLVM, :option:`-e` should be used, and :option:`-r` with mcode.
The files are first parsed, and then a elaboration is performed, which drives an analysis.
Effectively, analysis and elaboration are combined, but there is no explicit call to :option:`-a`.
With GCC/LLVM, code is generated during the elaboration.
With mcode, the simulation is launched after the elaboration.
All the units of the files are put into the `work` library.
But, the work library is neither read from disk nor saved.
Therefore, you must give all the files of the `work` library your design needs.
The advantages over the traditional approach (analyze and then elaborate) are:
* The compilation cycle is achieved in one command.
* Since the files are only parsed once, the compilation cycle may be faster.
* You don't need to know an analysis order.
* This command produces a smaller executable, since unused units and subprograms do not generate code.
.. HINT::
However, you should know that most of the time is spent in code generation and the analyze and elaborate command
generates code for all units needed, even units of ``std`` and ``ieee`` libraries.
Therefore, according to the design, the time for this command may be higher than the time for the analyze command
followed by the elaborate command.
.. WARNING::
This command is still under development. In case of problems, you should go back to the traditional way.
Design rebuilding commands
==========================
Analyzing and elaborating a design consisting of several files can be tricky, due to dependencies.
GHDL has a few commands for rebuilding a design.
.. index:: cmd importing files
.. _Import:command:
Import [``-i``]
---------------
.. option:: -i <[options] file...>
All the files specified in the command line are scanned, parsed and added into the libraries but as not yet analyzed.
No object files are created.
Its purpose is to localize design units in the design files.
The make command will then be able to recursively build a hierarchy from an entity name or a configuration name.
.. HINT::
* Note that all the files are added to the work library.
If you have many libraries, you must use the command for each library.
* Since the files are parsed, there must be correct files.
However, since they are not analyzed, many errors are tolerated by this command.
See :option:`-m`, to actually build the design.
.. index:: cmd make
.. _Make:command:
Make [``-m``]
-------------
.. option:: -m <[options] [library.]top_unit [arch]>
Analyze automatically outdated files and elaborate a design.
The primary unit denoted by the ``[library.]top_unit`` argument must already be known by the system, either because you
have already analyzed it (even if you have modified it) or because you have imported it.
A file may be outdated because it has been modified (e.g. you have just edited it), or because a design unit contained
in the file depends on a unit which is outdated.
This rule is recursive.
* With option ``--bind``, GHDL will stop before the final linking step.
This is useful when the main entry point is not GHDL and you're linking GHDL object files into a foreign program.
* With option ``-f`` (force), GHDL analyzes all the units of the work library needed to create the design hierarchy.
Outdated units are recompiled.
This is useful if you want to compile a design hierarchy with new compilation flags (for example, to add the ``-g``
debugging option).
.. IMPORTANT::
The make command will only re-analyze design units in the work library.
GHDL fails if it has to analyze an outdated unit from another library.
The purpose of this command is to be able to compile a design without prior knowledge of file order.
In the VHDL model, some units must be analyzed before others (e.g. an entity before its architecture).
It might be a nightmare to analyze a full design of several files if you don't have the ordered list of files.
This command computes an analysis order.
The make command fails when a unit was not previously parsed.
For example, if you split a file containing several design units into several files, you must either import these new
files or analyze them so that GHDL knows in which file these units are.
The make command imports files which have been modified.
Then, a design hierarchy is internally built as if no units are outdated.
Then, all outdated design units, using the dependencies of the design hierarchy, are analyzed.
If necessary, the design hierarchy is elaborated.
.. HINT::
This is not perfect, since the default architecture (the most recently analyzed one) may change while outdated design
files are analyzed.
In such a case, re-run the make command of GHDL.
.. index:: cmd generate makefile
Generate Makefile [``--gen-makefile``]
--------------------------------------
.. option:: --gen-makefile <[options] [library.]top_unit [arch]>
This command works like the make command (see :option:`-m`), but only a makefile is generated on the standard output.
.. index:: --gen-depends command
Generate dependency file command [``--gen-depends``]
----------------------------------------------------
.. option:: --gen-depends <[options] [library.]top_unit [arch]>
Generate a Makefile containing only dependencies to build a design unit.
This command works like the make and gen-makefile commands (see :option:`-m`), but instead of a full makefile only
dependencies without rules are generated on the standard output.
Theses rules can then be integrated in another Makefile.
.. _GHDL:options:
Options
=======
.. index:: IEEE 1164
.. index:: 1164
.. index:: IEEE 1076.3
.. index:: 1076.3
.. index:: WORK library
.. option:: --work=<LIB_NAME>
Specify the name of the ``WORK`` library. Analyzed units are always placed in the library logically named ``WORK``.
With this option, you can set its name.
By default, the name is ``work``.
`GHDL` checks whether ``WORK`` is a valid identifier.
Although being more or less supported, the ``WORK`` identifier should not be an extended identifier, since the
filesystem may prevent it from working correctly (due to case sensitivity or forbidden characters in filenames).
.. ATTENTION::
`VHDL` rules forbid you from adding units to the ``std`` library.
Furthermore, you should not put units in the ``ieee`` library.
.. HINT::
Since `849a25e0 <https://github.com/ghdl/ghdl/commit/849a25e02cfb359e3d9313060156b0643495548b>`__, this option can
be alternatively provided to several commands by prepending the library name to the top unit name.
See, for instance, :option:`-e`.
.. option:: --workdir=<DIR>
Specify the directory where the ``WORK`` library is located.
When this option is not present, the ``WORK`` library is in the current directory.
The object files created by the compiler are always placed in the same directory as the ``WORK`` library.
Use option :option:`-P <-P>` to specify where libraries other than ``WORK`` are placed.
.. option:: --std=<STANDARD>
Specify the standard to use. By default, the standard is ``93c``, which means VHDL-93 with relaxed rules.
For details on ``STANDARD`` values see section :ref:`VHDL_standards`.
.. IMPORTANT:: This option resets the effect of :option:`-frelaxed`, so it should be the first option.
.. option:: -fsynopsys
Allow the use of synopsys non-standard packages (``std_logic_arith``, ``std_logic_signed``, ``std_logic_unsigned``,
``std_logic_textio``).
These packages are present in the ieee library but without this option it's an error to use them.
The synopsys packages were created by some companies, and are popular.
However they are not standard packages, and have been placed in the `IEEE` library without the permission from the
``ieee``.
.. option:: --ieee=<IEEE_VAR>
.. index:: ieee library
.. index:: synopsys library
Select the ``IEEE`` library to use. ``IEEE_VAR`` must be one of:
none
Do not supply an `IEEE` library. Any library clause with the ``IEEE`` identifier will fail, unless you have created
your own library with the `IEEE` name.
standard
Supply an `IEEE` library containing only packages defined by ``ieee`` standards.
Currently, there are the multivalue logic system package ``std_logic_1164`` defined by IEEE 1164, the synthesis
packages ``numeric_bit`` and ``numeric_std`` defined by IEEE 1076.3, and the ``vital`` packages ``vital_timing`` and
``vital_primitives``, defined by IEEE 1076.4.
The version of these packages is defined by the VHDL standard used.
See section :ref:`VITAL_packages`, for more details.
synopsys
This option is now deprecated.
It is equivalent to ``--ieee=standard`` and ``-fsynopsys``.
To avoid errors, you must use the same `IEEE` library for all units of your design, and during elaboration.
.. option:: -P<DIRECTORY>
Add `DIRECTORY` to the end of the list of directories to be searched for library files.
A library is searched in `DIRECTORY` and also in `DIRECTORY/LIB/vVV` (where `LIB` is the name of the library and `VV`
the vhdl standard).
The `WORK` library is always searched in the path specified by the :option:`--workdir` option, or in the current
directory if the latter option is not specified.
.. option:: -fexplicit
When two operators are overloaded, give preference to the explicit declaration.
This may be used to avoid the most common pitfall of the ``std_logic_arith`` package.
See section :ref:`IEEE_library_pitfalls`, for an example.
.. WARNING::
This option is not set by default.
We don't think this option is a good feature, because it breaks the encapsulation rule.
When set, an operator can be silently overridden in another package.
You'd do better to fix your design and use the ``numeric_std`` package.
.. option:: -frelaxed
.. option:: -frelaxed-rules
.. IMPORTANT:: The effects of this option are reset by :option:`--std`, so it should be placed *after* that option.
Slightly relax some rules to be compatible with various other simulators or synthesizers:
* VHDL-87 file declarations are accepted;
* Default binding indication rules of VHDL-02 are used. Default binding rules are often used, but they are
particularly obscure before VHDL-02.
* Within an object declaration, allow references to the name (which references the hidden declaration).
This ignores the error in the following code:
.. code-block:: VHDL
package pkg1 is
type state is (state1, state2, state3);
end pkg1;
use work.pkg1.all;
package pkg2 is
constant state1 : state := state1;
end pkg2;
Some code (such as Xilinx packages) have such constructs, which are invalid.
(The scope of the ``state1`` constant starts at the `constant` keyword.
Because the constant ``state1`` and the enumeration literal ``state1`` are homographs, the enumeration literal is
hidden in the immediate scope of the constant).
This option also relaxes the rules about pure functions.
Violations result in warnings instead of errors.
.. option:: -fpsl
Enable parsing of PSL assertions within comments.
See section :ref:`PSL_implementation` for more details.
.. option:: --mb-comments, -C
Allow UTF8 or multi-bytes chars in a comment.
According to the VHDL standards before 2002, the only characters allowed in a source file (and that includes the
comments) are the graphical characters of the ISO 8859-1 character set.
This is incompatible with comments using UTF-8 or some other encoding.
This option lift this restriction.
.. option:: --syn-binding
Use synthesizer rules for component binding.
During elaboration, if a component is not bound to an entity using VHDL LRM rules, try to find in any known library an
entity whose name is the same as the component name.
This rule is known as the synthesizer rule.
There are two key points: normal VHDL LRM rules are tried first and entities are searched only in known libraries.
A known library is a library which has been named in your design.
This option is only useful during elaboration.
.. option:: --format=<FORMAT>
Define the output format of some options, such as :option:`--pp-html` or :option:`--xref-html`.
* By default or when :option:`--format=html2 <--format>` is specified, generated files follow the HTML 2.0 standard,
and colours are specified with `<FONT>` tags.
However, colours are hard-coded.
* If :option:`--format=css <--format>` is specified, generated files follow the HTML 4.0 standard, and use the CSS-1
file :file:`ghdl.css` to specify colours.
This file is generated only if it does not already exist (it is never overwritten) and can be customized by the user
to change colours or appearance.
Refer to a generated file and its comments for more information.
.. option:: --no-vital-checks
.. option:: --vital-checks
Disable or enable checks of restriction on VITAL units. Checks are enabled by default.
Checks are performed only when a design unit is decorated by a VITAL attribute.
The VITAL attributes are ``VITAL_Level0`` and ``VITAL_Level1``, both declared in the ``ieee.VITAL_Timing`` package.
Currently, VITAL checks are only partially implemented.
See section :ref:`VHDL_restrictions_for_VITAL` for more details.
.. option:: --PREFIX=<PATH>
Use :file:`PATH` as the prefix path to find commands and pre-installed (``std`` and ``ieee``) libraries.
.. option:: -v
Be verbose. For example, for analysis, elaboration and make commands, GHDL displays the commands executed.
.. option:: -o=<FNAME>
All the commands that perform a link (:option:`-e`, :option:`--elab-run`, :option:`--link`, :option:`-c`,
:option:`-m`, etc.) support overriding the location and name of the generated artifact.
.. option:: --time-resolution=<UNIT>
.. ATTENTION::
This feature is supported with *mcode* backend only.
It is not possible to support it with either LLVM or GCC backends, because it needs to apply globally.
Set the base time resolution of the simulation.
This option is supported in commands :option:`-a` and :option:`-r` only.
Allowed values are ``auto`` (default), ``fs``, ``ps``, ``ns``, ``us``, ``ms`` or ``sec``.
With LLVM/GCC, the value is fixed to ``fs``.
.. HINT::
When overriding the time resolution, all the time units that are used in the design must be larger.
Using units below the resolution will produce a failure.
Warnings
========
Some constructions are not erroneous but dubious.
Warnings are diagnostic messages that report such constructions.
Some warnings are reported only during analysis, others during elaboration.
.. HINT::
You could disable a warning by using the ``--warn-no-XXX`` or ``-Wno-XXX`` instead of ``--warn-XXX`` or ``-WXXX``.
.. HINT::
The warnings ``-Wbinding``, ``-Wlibrary``, ``-Wshared``, ``-Wpure``, ``-Wspecs``, ``-Whide``, ``-Wport`` are enabled
by default.
.. option:: --warn-library
Warns if a design unit replaces another design unit with the same name.
.. option:: --warn-default-binding
During analyze, warns if a component instantiation has neither configuration specification nor default binding.
This may be useful if you want to detect during analyze possibly unbound components if you don't use configuration.
See section :ref:`VHDL_standards` for more details about default binding rules.
.. option:: --warn-binding
During elaboration, warns if a component instantiation is not bound (and not explicitly left unbound).
Also warns if a port of an entity is not bound in a configuration specification or in a component configuration.
This warning is enabled by default, since default binding rules are somewhat complex and an unbound component is most
often unexpected.
However, warnings are still emitted if a component instantiation is inside a generate statement.
As a consequence, if you use the conditional generate statement to select a component according to the implementation,
you will certainly get warnings.
.. option:: --warn-reserved
Emit a warning if an identifier is a reserved word in a later VHDL standard.
.. option:: --warn-nested-comment
Emit a warning if a ``/*`` appears within a block comment (vhdl 2008).
.. option:: --warn-parenthesis
Emit a warning in case of weird use of parentheses.
.. option:: --warn-vital-generic
Warns if a generic name of a vital entity is not a vital generic name. This
is set by default.
.. option:: --warn-delayed-checks
Warns for checks that cannot be done during analysis time and are postponed to elaboration time.
This is because not all procedure bodies are available during analysis (either because a package body has not yet been
analysed or because `GHDL` doesn't read not required package bodies).
These are checks for no wait statements in a procedure called in a sensitized process and checks for pure rules of a
function.
.. option:: --warn-body
Emit a warning if a package body which is not required is analyzed. If a package does not declare a subprogram or a
deferred constant, the package does not require a body.
.. option:: --warn-specs
Emit a warning if an all or others specification does not apply.
.. option:: --warn-runtime-error
Emit a warning in case of runtime error that is detected during analysis.
.. option:: --warn-shared
Emit a warning when a shared variable is declared and its type it not a protected type.
.. option:: --warn-hide
Emit a warning when a declaration hides a previous hide.
.. option:: --warn-unused
Emit a warning when a subprogram is never used.
.. option:: --warn-others
Emit a warning is an `others` choice is not required because all the choices have been explicitly covered.
.. option:: --warn-pure
Emit a warning when a pure rules is violated (like declaring a pure function with access parameters).
.. option:: --warn-static
Emit a warning when a non-static expression is used at a place where the standard requires a static expression.
.. option:: --warn-error
When this option is set, warnings are considered as errors.
Diagnostics Control
===================
.. option:: -fcolor-diagnostics
.. option:: -fno-color-diagnostics
Control whether diagnostic messages are displayed in color. The default is on when the standard output is a terminal.
.. option:: -fdiagnostics-show-option
.. option:: -fno-diagnostics-show-option
Control whether the warning option is displayed at the end of warning messages, so that the user can easily know how
to disable it.
.. option:: -fcaret-diagnostics
.. option:: -fno-caret-diagnostics
Control whether the source line of the error is displayed with a caret indicating the column of the error.
Library commands
================
.. _Create_a_Library:
.. index:: create your own library
A new library is created implicitly, by compiling entities (packages etc.) into it:
``ghdl -a --work=my_custom_lib my_file.vhdl``.
A library's source code is usually stored and compiled into its own directory, that you specify with the
:option:`--workdir` option:
``ghdl -a --work=my_custom_lib --workdir=my_custom_libdir my_custom_lib_srcdir/my_file.vhdl``.
See also the :option:`-P <-P>` command line option.
Furthermore, GHDL provides a few commands which act on a library:
.. index:: cmd library directory
.. option:: --dir <[options] [libs]>
Displays the content of the design libraries (by default the ``work`` library).
All options are allowed, but only a few are meaningful: :option:`--work`, :option:`--workdir` and :option:`--std`.
.. index:: cmd library clean
.. _Clean:command:
.. option:: --clean <[options]>
Try to remove any object, executable or temporary file it could have created.
Source files are not removed.
The library is kept.
.. index:: cmd library remove
.. _Remove:command:
.. option:: --remove <[options]>
Acts like the clean command but removes the library too.
Note that after removing a design library, the files are not known anymore by GHDL.
.. index:: cmd library copy
.. option:: --copy <--work=name [options]>
Make a local copy of an existing library.
This is very useful if you want to add units to the ``ieee`` library:
.. code-block:: shell
ghdl --copy --work=ieee --ieee=synopsys
ghdl -a --work=ieee numeric_unsigned.vhd
.. _VPI_build_commands:
VPI/VHPI build commands
=======================
These commands simplify the compile and the link of a user VPI or VHPI module.
They are all wrappers: the arguments are in fact a whole command line that is executed with additional switches.
Currently a unix-like compiler (like `cc`, `gcc` or `clang`) is expected: the additional switches use their syntax.
The only option is `-v` which displays the command before its execution.
.. index:: cmd VPI compile
.. option:: --vpi-compile <command>
Add an include path to the command and execute it::
ghdl --vpi-compile command
This will execute::
command -Ixxx/include
For example, ``ghdl --vpi-compile gcc -c vpi1.c`` executes ``gcc -c vpi1.c -fPIC -Ixxx/include``.
.. _VPI_link_command:
.. index:: cmd VPI link
.. option:: --vpi-link <command>
Add a library path and name to the command and execute it::
ghdl --vpi-link command
This will execute::
command -Lxxx/lib -lghdlvpi
For example, ``ghdl --vpi-link gcc -o vpi1.vpi vpi1.o`` executes ``gcc -o vpi1.vpi vpi1.o --shared -Lxxx/lib -lghdlvpi``.
.. _VPI_cflags_command:
.. index:: cmd VPI cflags
.. option:: --vpi-cflags
Display flags added by :option:`--vpi-compile`.
.. index:: cmd VPI ldflags
.. option:: --vpi-ldflags
Display flags added by :option:`--vpi-link`.
.. index:: cmd VPI include dir
.. option:: --vpi-include-dir
Display the include directory added by the compile flags.
.. index:: cmd VPI library dir
.. option:: --vpi-library-dir
Display the library directory added by the link flags.
.. option:: --vpi-library-dir-unix
Display the library directory added by the link flags, forcing UNIX syntax.
.. _ieee_library_pitfalls:
IEEE library pitfalls
=====================
When you use options :option:`--ieee=synopsys <--ieee>`, the ``ieee`` library contains non standard packages such as
``std_logic_arith``.
These packages are not standard because there are not described by an IEEE standard, even if they have been put in the
`IEEE` library.
Furthermore, they are not really de-facto standard, because there are slight differences between the packages of Mentor
and those of Synopsys.
Furthermore, since they are not well thought out, their use has pitfalls.
For example, this description has an error during compilation:
.. code-block:: VHDL
library ieee;
use ieee.std_logic_1164.all;
-- A counter from 0 to 10.
entity counter is
port (val : out std_logic_vector (3 downto 0);
ck : std_logic;
rst : std_logic);
end counter;
library ieee;
use ieee.std_logic_unsigned.all;
architecture bad of counter
is
signal v : std_logic_vector (3 downto 0);
begin
process (ck, rst)
begin
if rst = '1' then
v <= x"0";
elsif rising_edge (ck) then
if v = "1010" then -- Error
v <= x"0";
else
v <= v + 1;
end if;
end if;
end process;
val <= v;
end bad;
When you analyze this design, GHDL does not accept it (two long lines have been split for readability):
.. code-block:: shell
ghdl -a --ieee=synopsys bad_counter.vhdl
bad_counter.vhdl:13:14: operator "=" is overloaded
bad_counter.vhdl:13:14: possible interpretations are:
../../libraries/ieee/std_logic_1164.v93:69:5: implicit function "="
[std_logic_vector, std_logic_vector return boolean]
../../libraries/synopsys/std_logic_unsigned.vhdl:64:5: function "="
[std_logic_vector, std_logic_vector return boolean]
../translate/ghdldrv/ghdl: compilation error
Indeed, the `"="` operator is defined in both packages, and both are visible at the place it is used.
The first declaration is an implicit one, which occurs when the `std_logic_vector` type is declared and is an element to
element comparison.
The second one is an explicit declared function, with the semantics of an unsigned comparison.
With some analysers, the explicit declaration has priority over the implicit declaration, and this design can be
analyzed without error.
However, this is not the rule given by the VHDL LRM, and since GHDL follows these rules, it emits an error.
You can force GHDL to use this rule with the *-fexplicit* option (see :ref:`GHDL:options` for further details).
However it is easy to fix this error, by using a selected name:
.. code-block:: VHDL
library ieee;
use ieee.std_logic_unsigned.all;
architecture fixed_bad of counter
is
signal v : std_logic_vector (3 downto 0);
begin
process (ck, rst)
begin
if rst = '1' then
v <= x"0";
elsif rising_edge (ck) then
if ieee.std_logic_unsigned."=" (v, "1010") then
v <= x"0";
else
v <= v + 1;
end if;
end if;
end process;
val <= v;
end fixed_bad;
It is better to only use the standard packages defined by IEEE, which provide the same functionalities:
.. code-block:: VHDL
library ieee;
use ieee.numeric_std.all;
architecture good of counter
is
signal v : unsigned (3 downto 0);
begin
process (ck, rst)
begin
if rst = '1' then
v <= x"0";
elsif rising_edge (ck) then
if v = "1010" then
v <= x"0";
else
v <= v + 1;
end if;
end if;
end process;
val <= std_logic_vector (v);
end good;
.. index:: Math_Real
.. index:: Math_Complex
.. HINT::
The ``ieee`` math packages (``math_real`` and ``math_complex``) provided with `GHDL` are fully compliant with the
`IEEE` standard.
|